Workspace upgrade failed

Description

This alert is triggered when an error occurs upgrading workspace data or an application.

Resolution Guidance

Impact When Active

  • System/User Experience Impact While Alert Is Active:
    • Definite Impact: Users are unable to perform any workspace-related tasks within the application.
    • Possible/Likely Impact: Certain application features or integrations may not function correctly.

How To Resolve

  • Go to the backend of the Relativity instance.
  • Verify the 'kCura Service Host Manager' Windows service is running.
  • If any one application is not working, restart the 'kCura Service Host Manager' Windows service.
  • Wait for 6 min so that all applications/services are deleted and re-created.
  • Refresh Kibana browser and the alert will be recovered.

Alert Details

The alert is active when an error occurs upgrading workspace data or an application.

Alert Condition Details

NameValueDescription
Rule TypeLog threshold
Data ViewLogs-*
Filter QueryWhen the count OF LOG ENTRIES with a message that matches Relativity.Data.WorkspaceUpgradeException
Threshold> 0Count greater than 0, alert triggers
Time Window1 hourVerified data for last 1 hour
Frequency1 minChecks for every 1 min
Return to top of the page
Feedback