Feedback
e3b1a0b6-5446-4ae0-ba70-bad506deca29
Bootstrap Failure
Description
This alert is triggered when a Relativity service is starting up, and fails to initialize an essential component. Here are a few of the essential components:
- The SQL connection used by the Relativity service
- The component used to read instance settings
Resolution Guidance
Impact When Active
- A BootstrapException logged in the Windows event logs indicates a fatal error initializing essential components during startup of a Relativity Service.
- This error suggests a critical issue that requires immediate attention.
- Due to this error, workspaces may not appear after logging in.
- Consequently, there will be issues with running any application functionality.
How To Resolve
- Go to the backend of the Relativity instance.
- Locate 'kCura Service Host Manager' Windows service is up and running
- If any one application/service is not working, restart the 'kCura Service Host Manager' Windows service.
- Wait for 5 min so that all applications/services are deleted and recreated.
- If the error still persists, please contact customer support, since it's a bootstrapping error.
Alert Details
The alert is active for the following condition in Relativity:
- When a BootstrapException is logged in the Windows event logs. This indicates a fatal error during the bootstrapping process, suggesting a critical issue that requires immediate attention.
Alert Condition Details
| Name | Value | Description |
|---|---|---|
| Rule Type | Elastic Query | |
| Data View | logs-* | |
| Filter Query | message: BootstrapException and message: The bootstrap operation failed | |
| Group | Count | |
| Threshold | > 0 | Count greater than 0, alert triggers |
| Time Window | 1 hour | Verified data for last 1 hour |
| Frequency | 1 min | Checks for every 1 minute |