e3b1a0b6-5446-4ae0-ba70-bad506deca29
Bootstrap Failure
Description
This alert is triggered when a Relativity service is starting up, and fails to initialize an essential component. Here are a few of the essential components:
- The SQL connection used by the Relativity service
- The component used to read instance settings
Resolution Guidance
Impact When Active
- A BootstrapException logged in the Windows event logs indicates a fatal error initializing essential components during startup of a Relativity Service.
- This error suggests a critical issue that requires immediate attention.
- Due to this error, workspaces may not appear after logging in.
- Consequently, there will be issues with running any application functionality.
How To Resolve
- Go to the backend of the Relativity instance.
- Locate 'kCura Service Host Manager' Windows service is up and running
- If any one application/service is not working, restart the 'kCura Service Host Manager' Windows service.
- Wait for 5 min so that all applications/services are deleted and recreated.
- If the error still persists, please contact customer support, since it's a bootstrapping error.
Alert Details
The alert is active for the following condition in Relativity:
- When a BootstrapException is logged in the Windows event logs. This indicates a fatal error during the bootstrapping process, suggesting a critical issue that requires immediate attention.
Alert Condition Details
Name |
Value |
Description |
Rule Type |
Elastic Query |
|
Data View |
logs-* |
|
Filter Query |
message: BootstrapException and message: The bootstrap operation failed |
|
Group |
Count |
|
Threshold |
> 0 |
Count greater than 0, alert triggers |
Time Window |
1 hour |
Verified data for last 1 hour |
Frequency |
1 min |